Treatment Overview
The Innotex Korea Mid-Urethral Sling System is a Korean-developed, state-of-the-art surgical solution designed to treat stress urinary incontinence (SUI) in women. This system uses a tension-free, monofilament polypropylene mesh sling that is placed beneath the mid-urethra to provide natural support, preventing urine leakage during activities such as coughing, sneezing, or physical exertion.
Developed through advanced biomedical engineering in Korea, the Innotex Sling System represents a new generation of minimally invasive uro-gynecologic technology, offering enhanced tissue integration, superior elasticity, and biocompatibility. Korean hospitals use this system extensively in both retropubic and transobturator approaches, guided by high-definition imaging and robotic precision.
Purpose & Benefits
Purpose:
- To correct stress urinary incontinence caused by weakened pelvic-floor muscles or urethral hypermobility.
- To provide a durable, minimally invasive alternative to open bladder suspension procedures.
- To maintain normal urethral function while reinforcing pelvic-floor stability.
Benefits:
- Developed in Korea with materials optimized for Asian pelvic anatomy and soft-tissue compatibility.
- Minimally invasive—small incisions, low bleeding risk, and short procedure time (20–30 minutes).
- Tension-free design maintains natural urinary flow.
- High success rate (85–95%) with long-term durability.
- Advanced mesh flexibility prevents stiffness or discomfort.
- In Korean clinics, enhanced by 3D endoscopic imaging, micro-tension calibration, and robotic-assisted sling positioning.
Ideal Candidates
The Innotex Mid-Urethral Sling System is ideal for:
- Women diagnosed with mild to moderate stress urinary incontinence.
- Patients with urethral hypermobility or weakened pelvic-floor muscles after childbirth or menopause.
- Those who have not improved with non-surgical methods such as pelvic-floor exercises, EMS therapy, or laser tightening.
- Women seeking a Korean-engineered, precision-based surgical solution with quick recovery and long-lasting results.
Not suitable for:
- Severe intrinsic sphincter deficiency (ISD) or advanced pelvic-organ prolapse.
- Patients with active urinary infections or prior severe mesh complications.
- Individuals with uncontrolled systemic conditions affecting healing.
Possible Risks & Complications
The Innotex Sling System is extremely safe and rigorously tested, but potential risks include:
- Temporary urinary retention or mild voiding difficulty.
- Short-term pelvic or groin discomfort.
- Minor vaginal bleeding or incision bruising.
- Rare mesh exposure or erosion.
- Transient urgency or mild infection (quickly treatable).
Korean uro-gynecology centers minimize these risks with real-time endoscopic monitoring, sterile microsurgical techniques, and custom-tension adjustment for every patient’s anatomy.
Surgical Techniques Used
Korean surgeons perform the Innotex Mid-Urethral Sling Procedure using advanced minimally invasive methods—either the retropubic or transobturator (TOT) approach—depending on patient anatomy and incontinence severity.
Procedure Steps:
- A small (1–1.5 cm) incision is made in the vaginal wall beneath the urethra.
- Two small skin punctures are created in the lower abdomen (retropubic route) or inner thighs (transobturator route).
- The Innotex polypropylene sling is inserted using specialized introducers and positioned under the mid-urethra.
- The sling is adjusted tension-free to support natural urethral closure without obstruction.
- Incisions are closed with absorbable sutures—no visible scars remain.
Korean Surgical Innovations Include:
- 3D laparoscopic or endoscopic visualization for enhanced anatomical precision.
- Micro-tension feedback systems for individualized sling placement.
- Flexible biocompatible mesh designed to match natural urethral movement.
- Robotic-assisted alignment systems in advanced hospitals for optimal accuracy.
- Hybrid procedures combining sling placement with pelvic rejuvenation or laser therapy.
Techniques Commonly Used in Korea:
- Innotex Retropubic Mid-Urethral Sling: For patients needing strong urethral support.
- Innotex Transobturator Sling (TOT): For patients prioritizing comfort and minimal groin pain.
- Single-Incision Mini Sling: For select cases requiring even smaller incisions and rapid healing.
Recovery & Aftercare
Recovery:
- Outpatient or 1-day hospital stay.
- Mild pelvic discomfort for 1–2 days; light activities can resume quickly.
- Full recovery and tissue integration within 4–6 weeks.
Aftercare:
- Avoid strenuous activity, sexual intercourse, and heavy lifting for 6 weeks.
- Maintain hydration and prevent constipation to reduce pelvic pressure.
- Regular follow-ups to monitor sling position and urinary function.
- Korean hospitals often include post-surgical EMS or biofeedback therapy to enhance pelvic-floor muscle recovery and maintain continence.
Results & Longevity
Results:
- Immediate or rapid improvement in bladder control.
- Reduction or elimination of urine leakage during exertion.
- Restored urethral support and pelvic stability.
- Minimal scarring and natural tissue integration.
Longevity:
- Results typically last 10–15 years or more.
- Korean precision in sling tensioning and placement ensures long-term success.
- Periodic pelvic maintenance programs extend results further.
- The high-quality Innotex mesh resists deformation and maintains its support over time.
Treatment Process in Korea
Why Korea is a Top Destination:
- Korea is a global pioneer in pelvic-floor reconstructive and incontinence surgery.
- The Innotex system was developed domestically, making Korean surgeons exceptionally skilled in its use.
- Integration of robotic surgery, high-resolution imaging, and 3D anatomical mapping ensures unmatched precision.
- Multidisciplinary care teams provide both functional and aesthetic restoration of the pelvic floor.
- Transparent pricing, fast scheduling, and international patient support attract women worldwide seeking advanced uro-gynecologic care.
Typical Procedure Flow:
- Consultation: Pelvic-floor examination, urodynamic testing, and ultrasound assessment.
- Preoperative Planning: Selection of surgical route (retropubic or transobturator).
- Anesthesia: Local, spinal, or light general anesthesia.
- Sling Placement: Innotex mesh positioned under the mid-urethra using image-guided precision.
- Verification: Real-time endoscopy ensures safe placement and correct tension.
- Closure: Absorbable sutures used for scarless incisions.
- Follow-Up: Regular evaluations at 1 week, 1 month, and 3 months post-surgery.
Unique Korean Innovations:
- 3D pelvic mapping for custom sling tensioning.
- Ultralight biocompatible Innotex mesh tailored for Korean anatomy.
- Robotic-assistance systems for precise intraoperative control.
- Comprehensive rehabilitation programs combining surgery with physiotherapy and rejuvenation.
- Aesthetic micro-suturing for invisible scars and enhanced comfort.
Cost Range (Details)
The cost of Innotex Mid-Urethral Sling Surgery in Korea depends on the surgical technique, hospital type, and post-surgery care:
- Standard Innotex Sling (Retropubic or TOT): ₩ 3,500,000 – 5,000,000 KRW (≈ US $2,700 – $3,800)
- Advanced or Robotic-Assisted Innotex Sling: ₩ 6,000,000 – 8,000,000 KRW (≈ US $4,600 – $6,100)
- Comprehensive Pelvic Rehabilitation Package: ₩ 8,000,000 – 10,000,000 KRW (≈ US $6,100 – $7,600)
- Hybrid or Premium Innotex Rejuvenation Package: ₩ 10,000,000 – 13,000,000 KRW (≈ US $7,600 – $9,900)
Korea offers cutting-edge medical care and international-grade outcomes at competitive prices, making it one of the most cost-effective destinations for advanced sling procedures.
Popular Clinics in Korea
- University-affiliated women’s hospitals performing Innotex-based uro-gynecologic surgeries.
- Gangnam uro-gynecology centers specializing in Innotex mid-urethral and transobturator sling systems.
- Women-only pelvic-floor and rejuvenation hospitals integrating surgery and rehabilitation.
- Postpartum recovery centers offering pelvic strengthening and continence therapy.
- International medical centers with English-speaking staff and personalized care programs.



